Shop

Delo Duopox SJ8665 Heat-Resistant Two-part Epoxy Adhesive 50ml

(5 customer reviews)

35,94 

DELO-DUOPOX SJ8665 is a high-strength 2-component epoxy adhesive suitable for electric motor applications, offering excellent temperature resistance up to.

Quick Product Inquiry

Send us a quick inquiry for this product. We will reply with availability, pricing, and delivery information.

SKU: ID489b61c822 Category:

Description

DELO-DUOPOX® SJ8665 is a room-temperature curing, high-strength 2-component epoxy adhesive with excellent temperature resistance up to +180 °C. Especially suitable for electric motor applications.

  • Pack size: 50 ml double cartridge
  • Also available in: 200 ml double cartridge, 8.4 kg bulk unit
Applications
  • Structural bonding of metals
  • Electronics and electric motor assembly
  • Components exposed to high temperatures (-40 °C to +180 °C)
  • Mechanical engineering, electrical engineering, and automotive industry
Features
  • High-strength adhesive with shear strength up to 32 MPa
  • Gap-filling and impact-resistant
  • Medium viscosity
  • Room-temperature curing: initial strength after 3.5 h, functional strength after 5 h, full cure after 7 days
  • Accelerated curing at +80 °C: full cure after 60 min
  • VOC-compliant according to GB33372-2020
  • Ready to use
Technical Data
Physical Properties
Color (cured) Black
Transparency Opaque
Mix ratio (vol. / wt.) 2:1 / 1.65:1
Density component A / B 1.16 / 1.41 g/cm³
Viscosity A / B 300,000 / 30,000 mPa·s
Processing time (20 g / 100 g, RT) 15 min / 40 min
Shrinkage (RT / 80 °C) 3 vol.-% / 3 vol.-%
Water absorption (24 h) 0.15 wt.-%
Mechanical Properties
Shear strength (Al/Al / Steel/Steel) 32 MPa / 24 MPa
Compressive shear strength 30 MPa
Tensile strength 46 MPa
Elongation at break 3.5 %
Shore hardness D (RT / 80 °C) 77 / 82
Elastic modulus 3300 MPa
Thermal Properties
Service temperature range -40 °C to +180 °C
Glass transition temperature (Tg) 126 °C
Decomposition temperature 294 °C
Thermal expansion (35-100 °C / 120-175 °C) 82 / 171 ppm/K

* All technical values determined under laboratory conditions at +23 °C / 50 % r.h.
Suitability for practical use must be verified for the specific application.

Application Notes
  • Apply using dual-chamber cartridge with static mixing nozzle
  • Clean and optionally roughen bonding surfaces
  • Curing can be accelerated with heat
Recommended Accessories
  • Mixing nozzle: DELO® Mixing Nozzle B 050 short
  • Dispensing gun: DELO-XPress
  • Cleaner: Delothen NK1 400 ml Spray
Storage & Shelf Life
  • Shelf life unopened: 12 months at +15 °C to +30 °C
  • Store dry, frost-free, and in original packaging

Hazard Identification (CLP) – Component A

Exclamation mark Environment

Signal word: Warning.

Hazard Statements (H-Sentences)
  • Causes skin irritation.
  • May cause allergic skin reactions.
  • Causes serious eye irritation.
  • Toxic to aquatic organisms, with long-lasting effects.
Precautionary Statements (P-Sentences)
Prevention:
  • Wear protective gloves (1-4 hours breakthrough time: recommended Viton® fluoroelastomer / short-term exposure < 15 min nitrile gloves).
  • Wear eye protection or face protection.
  • Avoid release to the environment.
  • Avoid inhaling vapors.
  • Wash thoroughly after use.
Response:
  • If on skin: Wash with plenty of water and seek medical advice if irritation occurs.
  • If in eyes: Rinse carefully with water for several minutes, remove contact lenses if possible, continue rinsing and immediately seek medical advice if irritation persists.
Storage and Disposal
  • Not applicable.

Hazard Identification (CLP) – Component B

Signal word: Danger.

Hazard Statements (H-Sentences)
  • Causes severe skin burns and eye damage.
  • May cause allergic skin reactions.
  • May harm the unborn child.
  • Damages organs with prolonged or repeated exposure.
  • Harmful to aquatic organisms, with long-lasting effects.
Precautionary Statements (P-Sentences)
Prevention:
  • Seek special instructions before use. Wear protective gloves (1-4 hours breakthrough time: recommended Viton® fluoroelastomer / short-term exposure < 15 min nitrile gloves).
  • Wear protective clothing, eye protection, or face protection.
  • Avoid release to the environment.
  • Avoid inhaling vapors.
  • Do not eat, drink, or smoke during use.
Response:
  • If inhaled: Immediately call the Poison Center or a doctor.
  • If swallowed: Immediately call the Poison Center or a doctor, rinse mouth, DO NOT induce vomiting.
  • If on skin (or hair): Immediately remove contaminated clothing, wash skin with water, immediately call the Poison Center or a doctor.
  • If in eyes: Rinse carefully with water for several minutes, remove contact lenses if possible, continue rinsing, and immediately call the Poison Center or a doctor.
Storage and Disposal
  • Not applicable.
Hazardous materials. The forwarding charges may be raised, if shipping to: DE, AT, NL, GB, CH, CZ, IT, ES, FI, NO, BE, IE, RO, PL, FR, PT, LU, DK, LI, GR, SE, SK, BG, SI, CA, LT, EE, LV, HR, SA,
Information on product safety (Manufacturer, Contact)

DELO Industrie Klebstoffe GmbH & Co. KGaA, DELO-Allee 1, 86949 Windach, GERMANY, +49 8193 9900-0, [email protected], www.delo.de

5 reviews for Delo Duopox SJ8665 Heat-Resistant Two-part Epoxy Adhesive 50ml

  1. charlotte.sun

    I’ve been using it for 2 weeks and I already see results!

  2. david_89

    Good customer service. Well packaged and secure.

  3. alexandre_fr

    Well packaged and delivered quickly.

  4. dominik_s

    Practical and functional.

  5. Olivia W.

    Very effective, I noticed a change in just a week. Looks even nicer in real life.

Add a review

Your email address will not be published. Required fields are marked *